Rectifier and control
Converts the vessel's electrical supply to direct current. In automatic mode, it uses the potential measured by reference electrodes to adjust the output to the anodes.
MARINE TECHNICAL GUIDE
Operation, components and advantages over galvanic anodes.
IMPRESSED CURRENT CATHODIC PROTECTION
ICCP protects submerged hull metal using controlled electrical current. Reference electrodes measure its electrical potential and the rectifier adjusts protective current accordingly. The system therefore regulates protection during vessel operation.
Principle diagram. Anodes and reference electrodes are electrically insulated from the hull; their positions are defined during engineering.
EXPLORE THE COMPONENTS
The rectifier powers the system and regulates current based on the measured potential. Its positive output connects to the anodes and its negative output to the hull.
SYSTEM COMPONENTS
Power supply, current delivery and measurement: each element has a different role in the ICCP system.

Converts the vessel's electrical supply to direct current. In automatic mode, it uses the potential measured by reference electrodes to adjust the output to the anodes.

Their active titanium surface, coated with mixed metal oxides, delivers protective current into the water. Shape, capacity and distribution are selected for the structure being protected.

Measure hull potential relative to seawater. This signal tells the controller how to regulate protection; their role is measurement, not supplying protective current.
Installation also includes conductors, insulation and seals. Cofferdams form internal enclosures around through-hull fittings; their construction and access are defined in the installation engineering.
ADVANTAGES OVER GALVANIC ANODES
SELEC designs and installs ICCP systems on vessels. This comparison shows how the technology improves protection control and reduces sacrificial anode replacement requirements.
| Aspect | Galvanic system | Automatic ICCP |
|---|---|---|
| Current source | The electrochemical potential difference between the sacrificial anode and the structure. | A rectifier powered by the installation. |
| Response to changes | Depends on anode material, quantity and environmental conditions. | Regulates output based on the potential measured by reference electrodes. |
| Service life and replacement | Sacrificial anodes with indicative replacement cycles of 2–3 years, depending on consumption. | System with a 20-year design life and low-consumption MMO anodes, with system maintenance. |
| Hydrodynamic drag | Anodes projecting from the hull add hydrodynamic drag. | Low-profile or flush-mounted anodes reduce this contribution to drag and support fuel savings. |
| Monitoring | Requires measurements and inspections to assess protection. | Allows operating data to be viewed and logging, alarms and remote monitoring to be integrated. |
An ICCP solution developed for each vessel. We specify power, anodes and control for the hull and its operation, combining manufacturing, installation, commissioning and support throughout system life.
Fewer projections help reduce hull drag.
Water must flow around components projecting from the hull surface.
Low-profile installation reduces the anodes' contribution to hydrodynamic drag.
Conceptual illustration of projecting and flush-mounted anodes. It is not a flow simulation or a quantified saving.
Anode shape, quantity and location affect hull drag. By reducing projections, ICCP can reduce the energy required to maintain vessel speed.
Savings are assessed using propulsion fuel consumption, normal operating speed, days at sea and the arrangement of anodes being replaced.
Illustrative example: if annual propulsion consumption is 500,000 litres and a vessel assessment estimates a 1% reduction, gross savings would be 5,000 litres per year. Their value is calculated using the fuel price.
The 1% figure is an assumption for this example. Net benefit also takes ICCP electricity consumption and maintenance into account.