Portable rectifiers
EC-2405 / EC-2415
Current injection for cathodic protection testing.
The EC-2405 and EC-2415 portable rectifiers are electronically regulated DC power supplies with an ON/OFF interrupter. They support current requirement tests, electrical isolation testing, design studies and cathodic protection system maintenance.
- Constant-voltage or constant-current regulation.
- Configurable limits to protect the equipment and installation.
- ON/OFF cycling with external synchronisation capability.
APPLICATIONS
Electrical isolation testing of structures.
Design studies and maintenance.
TEST CONTROL
Inject current.
Assess the response.
Output control, integrated interruption and portable construction for cathodic protection surveys and electrical isolation tests.
ELECTRONIC REGULATIONThe current each test requires.+
Switch-mode constant-voltage or constant-current regulation, with voltage, current and power limits. A colour LCD displays input and output variables, equipment status and configured limits; ten memory banks allow output settings to be recalled.
INTEGRATED ON/OFF INTERRUPTERContinuous injection or synchronised cycles.+
Select one of five preset ON/OFF programmes or operate continuously. The synchronisation input coordinates one or more units using an external GPS interrupter. The five standard cycles are selected from the control panel.
BATTERIES AND EXTERNAL POWERPower for different working conditions.+
Internal batteries support field testing. The supplied external power supply charges the batteries and powers the equipment during extended operation.
BUILT FOR FIELDWORKAn enclosure for demanding work.+
High-strength ABS enclosure resistant to water, dust and impact. Includes a pressure-relief valve, robust latches and a padlock eye. Inputs and outputs have overload-protection fuses.
SELECTING YOUR INSTRUMENT
Two models.
One control system.
EC-2405: up to 5 A. EC-2415: up to 15 A. Both models include electronic regulation, an ON/OFF interrupter, internal batteries and an external power supply.
Custom cycle times can be specified when ordering, at no additional charge.
Download datasheet (PDF) ↓| EC-2405 | Output current up to 5 A |
|---|---|
| EC-2415 | Output current up to 15 A |
| Regulation | Constant voltage or current |
| Display | Colour LCD |
| Cycling | 5 standard ON/OFF programmes and continuous mode |
| Standard ON / OFF times (s) | 0,7 / 0,3 · 0,3 / 0,7 · 4 / 1 · 5 / 2 · 8 / 2 |
| Synchronisation | External interrupter input |
| Output-setting memory | 10 banks |
| Configurable limits | Voltage, current and power |
| Enclosure | Water-, dust- and impact-resistant ABS |
| Instrument dimensions | 270 × 246 × 174 mm, excluding accessory bag |
| Weight | 9 kg, including accessories |
| Internal batteries | 2 rechargeable sealed lead-acid gel batteries (VRLA), 12 V / 7 Ah each |
| External power | Power supply included |

WHAT'S INCLUDED
Instrument and accessories.
Standard supply includes the instrument and the following accessories:
- EC-2405 or EC-2415 unit.
- SPEAKON cable to red and black crocodile clips.
- External power supply: 24 V / 5 A for EC-2405 or 24 V / 14.5 A for EC-2415.
- Accessory carry bag.
COMMON QUESTIONS
Frequently asked
questions.
What is a portable rectifier used for in a survey?+
It injects current to assess a structure's response during cathodic protection testing. Its ON/OFF interrupter supports measurements with current applied and interrupted.
Can cycle times be customised?+
Yes. Standard times can be adjusted to specific requirements when ordering, at no additional charge.
Does the stated weight include accessories?+
Yes. The stated 9 kg includes the instrument and its accessories.